Subject: Bench Check Window & Seat Motors
Window and seat motors can be checked on the bench with a power supplied from a battery pack, battery charger or jumper wires from a 6V or 12V battery which ever is applicable. Both motors have the same color coded wires. black, green, yellow and red.
A word of caution: Do not leave positive power connected to
the green wire for an extended time. The motor will over heat.
Be sure to secure motor from movement before testing. Gil Baumgartner |
|